Partial physeal arrest after temporary transphyseal pinning--a case report.

2.50
Hdl Handle:
http://hdl.handle.net/10143/56515
Title:
Partial physeal arrest after temporary transphyseal pinning--a case report.
Authors:
Horn, Joachim; Kristiansen, Leif Pål; Steen, Harald
Citation:
Partial physeal arrest after temporary transphyseal pinning--a case report. 2008, 79 (6):867-9notActa Orthop
Additional Links:
http://dx.doi.org/10.1080/17453670810016975

Full metadata record

DC FieldValue Language
dc.contributor.authorHorn, Joachim-
dc.contributor.authorKristiansen, Leif Pål-
dc.contributor.authorSteen, Harald-
dc.date.accessioned2009-03-20T08:23:40Z-
dc.date.available2009-03-20T08:23:40Z-
dc.date.issued2008-12-
dc.identifier.citationPartial physeal arrest after temporary transphyseal pinning--a case report. 2008, 79 (6):867-9notActa Orthopen
dc.identifier.issn1745-3682-
dc.identifier.pmid19085507-
dc.identifier.doi10.1080/17453670810016975-
dc.identifier.urihttp://hdl.handle.net/10143/56515-
dc.language.isoenen
dc.relation.urlhttp://dx.doi.org/10.1080/17453670810016975en
dc.subjectOrtopedisk kirurgi: 784en
dc.subjectFysikalsk medisin og rehabilitering: 764en
dc.subject.meshBone Wiresen
dc.subject.meshChilden
dc.subject.meshChild, Preschoolen
dc.subject.meshFemaleen
dc.subject.meshFemoral Fracturesen
dc.subject.meshFracture Fixation, Intramedullaryen
dc.subject.meshGrowth Plateen
dc.subject.meshHumansen
dc.subject.meshLeg Length Inequalityen
dc.subject.meshMagnetic Resonance Imagingen
dc.titlePartial physeal arrest after temporary transphyseal pinning--a case report.en
dc.typeJournal articleen
dc.typepeer revieweden
dc.contributor.departmentDepartment of Orthopedics, Rikshospitalet University Hospital, Oslo, Norway. joachim.horn@rikshospitalet.noen
dc.identifier.journalActa orthopaedicaen